The ITFD's flow laboratory is equipped with several wind tunnels and test benches as well as modern measurement technology. In addition to a thermal wind tunnel, which can be operated open or closed, there is also a transparent suction wind tunnel and a free-blowing wind tunnel.

Thermal wind tunnel

Characteristics
Max. mass flow3.5 kg/s
Max. pressure ratio1,6
Temperature range20 °C to 120 °C
Turbulence intensity0.2 % to 12 %
Application examplesHeat transfer measurements, research on transitional boundary layers, turbulence structure, turbulence spot kinematics, riblets
Measurement technologye.g. LDA, CTA, hot film, pneumatic probes, IR thermography, heat transfer

Transparent suction wind tunnel

Characteristics
Max. mass flow 0.25 kg/s
Max. pressure ratio 0,5
Temperature range Ambient temperature
Turbulence intensity 0.1 % to 4 %
Width of flow cross-section 500 mm
Height of flow cross-section 5 mm to 100 mm
Application examples Development of flow measurement technology, acquisition of validation data for the DNS, generation of a trained gap flow
Measurement technology e.g. LDA, CTA, hot film, pneumatic probes, IR thermography

Free-blowing wind tunnel

Characteristics
Max. mass flow 6 kg/s
Temperature range Ambient temperature
Turbulence intensity approx. 1 %
Jet diameter 500 mm
Application examples Determination of lift, drag and moment coefficients on aerofoil profiles and rotor blades
Measurement technology Pressure distribution, force and torque sensors